G.8272 / G.8273.1 compliant PRTC (±100nsec from UTC,
MTIE<100nsec) while locked to GNSS
During GNSS outage: time holdover using a
G.811 PRC / G.8272 PRTC Sync-E input
− Traceable to G.811 PRC: TimeError
< UTC +/-1μsec for 24 hrs
− Traceable to G.8272 PRTC: TimeError
< UTC +/- 1μsec for 72 hrs
表示
GPS/ GNSS 受信状態と総合フォールト表示のLED
Syncjack™ monitoring and assurance tools
Clock Accuracy for up to two clock probes – computing
TE and TIE of physical clocks
Calculation TE/TIE between physical source and
reference signals
Programmable source and reference signals including
SyncE, GNSS, PTP recovered clock.
TE/TIE raw data collection and export to server
Clock Analysis for up to two PTP clock probes – packet
TE/TIE
Calculation of packet TE/TIE between physical reference
signal and timestamps within the PTP packets
Programmable reference signals including SyncE and
GNSS
TE/TIE raw data collection and export to server
Integrated with Ensemble Controller Sync Director
Management and security
In-band management (over PTP / Sync-E port)
Remote CLI – Telnet & SSH (Secure Shell)
Separate MGMT IP & PTP address
VLAN and untagged
System software download via TFTP & SCP
(secure copy)
Enable to disable each of the protocol via CLI
Alarm log
Syslog
Remote authentication via RADIUS
Remote, secured backup and restore
Remote, secured SW upgrade
Low touch provisioning using configuration file
Multi-level user access
Access control list (ACL)
Full management using SNMP v2 / v3 including
authentication and encryption
LLDP
Alarms, inventory and traps reporting to NMS
Managed by ADVA Ensemble Controller and Ensemble
Sync Director, including GNSS assurance toolkit